Switch Virtual Console



Battle it out or cooperate with players online. Compatible games include Animal. Since the Nintendo Switch has been a major success, Nintendo should bring Virtual Console for Switch gamers who would love to revisit classic games. All of the following consoles should be available on VC Nintendo: NES Game Boy SNES Nintendo 64 Game Boy Color Game Boy Advance GameCube Nintendo DS (if Nintendo has time) Wii Sega: Game Gear Genisis Dreamcast. The inclusion of the Virtual Console on the Switch could help the company hit its 20-million-unit goal, but the Switch is popular enough to possibly do this without the Virtual Console. For a limited time, get a free $20 Target gift card with your purchase of a select Nintendo Switch Lite system. Learn more Offer valid 3/28/21 - 4/3/21 at Target, while supplies last. Virtual Console for Nintendo Switch? The Wii and Wii U all had a Virtual Console, so what is taking Nintendo so long to put one on the Switch?

Make your games even better

Enhance your games with features like online play, cloud saves, and more. Individual and Family Memberships are available.

Animal Crossing: New Horizons

Invite friends to your island paradise for a virtual get-together via online play.

Mario Kart 8 Deluxe

Play the Grand Prix, VS Race, and Battle modes online with up to 12 players.

Super Smash Bros. Ultimate

Nintendo switch virtual console library

Go 1-on-1 with a friend or hold a 4-player free-for-all when you brawl online.

Nintendo 64 Virtual Console Switch

Nintendo Entertainment System

Play—or replay—classic games like Super Mario Bros.™, Metroid™, Kirby’s Adventure™, and Yoshi™.

Switch virtual console rumors

Super Nintendo Entertainment System

Jump into favorites like Super Mario Kart™, Super Metroid™, The Legend of Zelda™: A Link to the Past™, Donkey Kong™ Country™, and more.

Switch virtual console list

Featured offer: PAC-MAN™ 99

Test your chomping chops in this 99-player PAC-Royale where you compete to be the last PAC-MAN standing. Nintendo Switch Online members can download and play the online mode of the game at no extra cost.

Save Data Cloud

Pokemon switch virtual console

Your save data will be automatically connected to your Nintendo account and stored online for compatible games. This makes it easy to retrieve your game data if you lose your system or start using a new one.

Nintendo Switch Online App

Open the app on your smartphone or tablet to voice chat in compatible games. Plus, enjoy special features for games including Animal Crossing: New Horizons, Super Smash Bros. Ultimate, and Splatoon 2.

Make the most of your Nintendo Switch™ system with Nintendo Switch Online

Try it for 7 days free.1 Sign up on your system today!

Individual Membership

Designed for one Nintendo Account holder. Affordable and convenient, in your choice of 1-, 3-, and 12-month options.

1 Month3 Months12 Months
$3.99 USD$7.99 USD$19.99 USD
Save $3.982Save $27.89

For a limited time, get 200 Gold Points with a purchase or renewal of a 12-month Individual Membership!4

Access Nintendo Switch Online right from your system and sign up for your free 7-day trial

You can get the latest info on Nintendo Switch Online from the Nintendo Switch HOME Menu.

And if you’re not yet a member, you can sign up for a free trial and enjoy the service for a full week!

ON THIS PAGE

EX4550 Switches Hardware Overview

Juniper Networks EX4550 Ethernet Switches providehigh-density 10-gigabit ports for aggregation layers and data centertop-of-rack deployments, and provide options for data center optimizedairflow (hot aisle/cold aisle). EX4550 switches have a base port densityof 32 fixed 10-Gigabit SFP+ or 10-Gigabit Ethernet BASE-T (10GBASE-T)ports that you can scale up to 48 ports by installing the optionalexpansion modules. You can configure EX4550 switches in a Virtual Chassis, or in a mixed Virtual Chassis withJuniper Networks EX4200 Ethernet Switches or Juniper Networks EX4500Ethernet Switches or both, in a total of up to 10 members.

You can expand the number of ports on an EX4550 switch by installingup to two optional expansion modules in the module slots on eitherside of the chassis.

The optional modules for an EX4550 switch are:

  • 8-port 10-Gigabit SFP+ expansion module—Provideseight ports for eight 1-gigabit small form-factor pluggable (SFP)transceivers or eight 10-gigabit small form-factor pluggable (SFP+)transceivers. You can install a total of eight SFP and SFP+ transceiversin any combination in these eight ports.

  • 8-port 10GBASE-T expansion module—Provides eightports for 100-Megabit Ethernet BASE-T, 1-Gigabit Ethernet BASE-T,or 10-Gigabit Ethernet BASE-T RJ-45 connectors.

  • 2-port 40-Gigabit QSFP+ expansion module—Providestwo ports for 40-gigabit quad small form-factor pluggable (QSFP+)transceivers.

  • 128-Gigabit Virtual Chassis module—Provides twodedicated Virtual Chassis ports (VCPs) for connecting the switch ina Virtual Chassis. You can also connect Virtual Chassis members usingthe SFP+ network ports, SFP+ expansion module ports, 10GBASE-T networkports, 10GBASE-T expansion module ports, and QSFP+ expansion moduleports configured as VCPs.

You can manage EX4550 switches by using the same interfacesthat you use for managing other devices running Juniper Networks Junosoperating system (Junos OS)—the CLI, the J-Web graphicalinterface, and Junos Space.

Benefits of the EX4550 Switch

Compact solution—The EX4550 switch supports up to 48 10-GigabitEthernet ports in a 1 rack unit (1 U) chassis.

Support for Virtual Chassis—EX4550 switches support VirtualChassis technology. You can interconnect up to 10 EX4200 switches,EX4500 switches, or EX4550 switches to form a Virtual Chassis.

Energy efficiency—The 10-Gigabit Ethernet fiber portsconsume less than five watts and the 10-Gigabit Ethernet copper portsconsume less than nine watts, thereby offering a low power solutionfor top-of-rack, end-of-row, and aggregation deployments.

Software

Juniper Networks EX Series Ethernet Switches run Junos OS, whichprovides Layer 2 and Layer 3 switching, routing, and security services.The same Junos OS code base that runs on EX Series switches also runson all Juniper Networks M Series, MX Series, and T Series routers,and SRX Series Services Gateways. For information about installingsoftware for your switch, see Software Installation.

EX4550 Switches First View

EX4550 switches provide connectivity for high-density 10-GigabitEthernet data center top-of-rack, enterprise, and campus aggregationand core deployments. EX4550 switches can be used in large branchoffices, campus wiring closets, and data centers where they can bepositioned as the top device in a rack to provide connectivity forall devices in the rack.

EX4550 switches are available in two base switches—a 32-portSFP+ based switch (EX4550-32F), which provides 32 fixed 10-GigabitSFP+ ports in which you can install 1-gigabit SFP or 10-gigabit SFP+transceivers and a 32-port 10GBASE-T based switch (EX4550-32T), whichprovides 32 fixed 10-Gigabit Ethernet BASE-T ports in which you caninstall 100-Megabit, 1-Gigabit, or 10-Gigabit BASE-T connectors. See EX4550 Switch Models.

EX4550 switches have different airflow directions in the chassis.EX4550 switches provide two module slots, each of which can houseany one of the following optional modules:

  • 8-port 10-Gigabit SFP+ expansion module

  • 8-port 10GBASE-T expansion module

  • 2-port 40-Gigabit QSFP+ expansion module

  • 128-Gigabit Virtual Chassis module

Figure 1 shows the frontpanel of an EX4550-32F switch.

Figure 2 shows the frontpanel of an EX4550-32T switch.

Figure 3 shows the rear panelof an EX4550 switch withpower supplies and fan modules installed.

To provide carrier-class reliability, EX4550 switches include:

  • Dual redundant, load-sharing power supplies that are hot-insertableand hot-removable field-replaceable units.

  • Three fan modules, which are field-replaceable units (FRUs).

  • Redundant Routing Engines in a Virtual Chassis configuration.This redundancy enables graceful Routing Engine switchover (GRES).

  • Junos OS with its modular design that enables failed systemprocesses to gracefully restart.

Switch

Optional Modules

EX4550switches support four types of optional modules: an 8-port 10-GigabitEthernet SFP+ expansion module, an 8-port 10GBASE-T expansion module,a 2-port 40-Gigabit Ethernet QSFP+ expansion module, and a 128-GigabitVirtual Chassis module. You can install up to two modules, in anycombination of these modules, one in each of the module slots. Thereis one module slot on the front panel and one on the rear panel ofthe switch.

Table 1 shows the modulemodel numbers, names of the optional modules with a short description,and the Junos OS release in which each module was released.

Table 1: Optional Modules in EX4550Switches

Model Number

Module Name

Description

First Junos OS Release

EX4550-EM-8XSFP

8-port 10-Gigabit SFP+ expansion module

An SFP+ expansion module can house up to eight 10-gigabit SFP+transceivers or 1-gigabit SFP transceivers or a combination of SFP+and SFP transceivers. You can use the ports on this expansion moduleto connect the switch to other devices. You can also configure theseports as VCPs and use them to connect the EX4550 switch with EX4200,EX4500, or EX4550 switches to form a Virtual Chassis.

12.2R1

EX4550-EM-8XT

8-port 10GBASE-T expansion module

A 10GBASE-T expansion module can house up to eight 100-Megabit,1-Gigabit, or 10-Gigabit Ethernet BASE-T connectors. You can use theports on this expansion module to connect the switch to other devices.You can also configure these ports as VCPs and use them to interconnectEX4550 switches to form a Virtual Chassis.

12.2R4

EX4550-EM-2QSFP

2-port 40-Gigabit QSFP+ expansion module

A QSFP+ expansion module has two ports, each of which can housea 40-Gigabit QSFP+ connector. You can also configure these ports asVCPs and use them to interconnect EX4550 switches to form a VirtualChassis.

13.2X50-D10

Note: Starting with Release 13.2X50-D15, you can configure QSFP+ asVCPs.

EX4550-VC-128G

128-Gigabit Virtual Chassis module

You can install the 128-Gigabit Virtual Chassis module in theEX4550 switch to connect the switch to other switches in a VirtualChassis configuration. The Virtual Chassis module has two dedicatedVCPs, using which you can connect the EX4550 switch with EX4200, EX4500,or EX4550 switches to form a Virtual Chassis.

12.2R1

Virtual Chassis

You can interconnect the EX4550 switch with EX4200, EX4500,or EX4550 switches to form a Virtual Chassis. You can operate theseinterconnected switches as a single, logical device with a singleIP address.

You can interconnect a maximum of 10 EX4550 switches to forma Virtual Chassis composed exclusively of EX4550 switches. You caninterconnect EX4200 switches or EX4500 switches or both with EX4550switches to form a mixed Virtual Chassis that has a maximum of 10switches. See Understanding EX4200, EX4500, and EX4550 Virtual Chassis Hardware Configurations.

You can use the following ports to connect an EX4550 switchin a Virtual Chassis:

  • Dedicated VCPs on the Virtual Chassis module installedin the switch

  • SFP+ network ports and SFP+ expansion module ports configuredas VCPs

  • 10GBASE-T Ethernet network ports or 10GBASE-T expansionmodule ports configured as VCPs

  • QSFP+ expansion module ports configured as VCPs

Note

You can use the 10GBASE-T Ethernet network ports, 10GBASE-Texpansion module ports, and QSFP+ expansion module ports configuredas VCPs to interconnect only EX4550 switches in a Virtual Chassis.These ports cannot be used to connect an EX4550 switch with an EX4200switch or an EX4500 switch in a Virtual Chassis.

Note

Installing the Virtual Chassis module is not mandatory for usingan EX4550 switch in a Virtual Chassis configuration.

For information about understanding and configuring VirtualChassis, see EX2200, EX3300, EX4200, EX4500 and EX4550 Virtual Chassis.

Power Supplies

EX4550 switchessupport AC or DC power supplies with different airflow directions.Power supplies for the EX4550 switch are hot-removable and hot-insertableFRUs. All the EX4550 switch models, except the EX4550-32F-S switchesare shipped with one power supply pre-installed in the rear panelof the switches. EX4550-32F-S switches are not shipped with pre-installedpower supplies; you must order them separately.

You caninstall a second AC or DC power supply in the EX4550 switches. See AC Power Supply in EX4550 Switches and DC Power Supply in EX4550 Switches

Each power supply has a label—AFO—on the faceplate of the powersupply that indicates the direction of airflow. AFO labels indicate front-to-back airflow. See Cooling System and Airflow in an EX4550 Switch.

Caution

Do not mix:

  • AC and DC power supplies in the same chassis.

  • Power supplies with different airflow labels (AFO) in the same chassis.

Fan Modules

Fan modules forthe EX4550 switches are hot-insertable and hot-removable field-replaceableunits (FRUs).

All the EX4550 switchmodels, except the EX4550-32F-S switches are shipped with three fan modules pre-installed in therear panel of the switches. EX4550-32F-S switches are not shipped with pre-installed fanmodules; you must order them separately.

Two variants of fan modules are available, each with a differentairflow direction—back-to-front airflow, indicated by the label AIR OUT (AFO). See Cooling System and Airflow in an EX4550 Switch.

Caution

Do not mix fan modules with different airflow labels (AIR OUT (AFO)) inthe same chassis.

Components on the EX4550 Switch

Figure 4 shows the componentson the front panel of an EX4550-32F switch (with the module slot coverpanel installed).


Figure 5 shows the componentson the front panel of an EX4550-32T switch (with the module slot coverpanel installed).


Figure 6 shows the componentson the rear panel of an EX4550 switch (with the module slot coverpanel, an AC power supply, and three fan modules installed).

Note

The protective earthing terminal is located on the left sideof the chassis. See Connect Earth Ground to an EX Series Switch.

EX4550 Switch Models

Table 2 lists the availableEX4550 switches.

Table 2: EX4550Switch Model Number, Shipped Components, and Supported Junos OS Release

Model Number

Number and Types of Ports

Direction of Airflow

Fan Modules

Power Supply

First Junos OS Release

EX4550-32F-AFI

32-port 10-Gigabit SFP+

Back-to-front—air intake to cool the chassis isthrough the vents on the rear panel of the chassis, and hot air exhauststhrough the vents on the front panel of the chassis.

Three fan modules; each with an

One AC power supply (with power cord) with an

12.2R1

EX4550-32F-AFO

32-port 10-Gigabit SFP+

Front-to-back—air intake to cool the chassis isthrough the vents on the front panel of the chassis, and hot air exhauststhrough the vents on the rear panel of the chassis.

Three fan modules; each with an

One AC power supply (with power cord) with an

12.2R1

EX4550-32F-DC-AFI

32-port 10-Gigabit SFP+

Back-to-front—air intake to cool the chassis isthrough the vents on the rear panel of the chassis, and hot air exhauststhrough the vents on the front panel of the chassis.

Three fan modules; each with an

One DC power supply with an

12.2R1

EX4550-32F-DC-AFO

32-port 10-Gigabit SFP+

Front-to-back—air intake to cool the chassis isthrough the vents on the front panel of the chassis, and hot air exhauststhrough the vents on the rear panel of the chassis.

Three fan modules; each with an

One DC power supply with an

12.2R1

EX4550-32F-S

32-port 10-Gigabit SFP+

Fan modules for this model are not shipped by default;you must separately order either three AIR OUT (AFO) labelled or threeAIR IN (AFI) labelled fan modules.

Power supplies for this model are not shipped by default;you must separately order either AC power supplies or DC power supplies.

12.3R5

EX4550-32T-AFI

32-port 10-Gigabit BASE-T

Back-to-front—air intake to cool the chassis isthrough the vents on the rear panel of the chassis, and hot air exhauststhrough the vents on the front panel of the chassis.

Three fan modules; each with an

One AC power supply (with power cord) with an

12.2R4

EX4550-32T-AFO

32-port 10-Gigabit BASE-T

Front-to-back—air intake to cool the chassis isthrough the vents on the front panel of the chassis, and hot air exhauststhrough the vents on the rear panel of the chassis.

Three fan modules; each with an

One AC power supply (with power cord) with an

12.2R4

EX4550-32T-DC-AFI

32-port 10-Gigabit BASE-T

Back-to-front—air intake to cool the chassis isthrough the vents on the rear panel of the chassis, and hot air exhauststhrough the vents on the front panel of the chassis.

Three fan modules; each with an

One DC power supply with an

12.2R4

EX4550-32T-DC-AFO

32-port 10-Gigabit BASE-T

Front-to-back—air intake to cool the chassis isthrough the vents on the front panel of the chassis, and hot air exhauststhrough the vents on the rear panel of the chassis.

Three fan modules; each with an

One DC power supply with an

12.2R4

Note

The optional modules, the Virtual Chassis cable, the VirtualChassis cable connector retainers, and transceivers are not part ofthe EX4550 switch shipping configuration. If you want to purchaseany of these components, power supplies, or fan modules for yourswitch, you must order them separately.

Identifying EX4550 Switch Models

Purpose

Identify the model number of your EX4550 switch.

Action

Check the value of the FRU Model Numberfield in the Routing Engine section in the output of the show chassis hardware extensive CLI command.

user@switch> show chassis hardwareextensive

Nintendo Switch Virtual Console Game List

The model number of your switch is one of the following:

Switch Virtual Console Games

  • EX4550-32F-AFI

  • EX4550-32F-AFO

  • EX4550-32F-DC-AFI

  • EX4550-32F-DC-AFO

  • EX4550-32T-AFI

  • EX4550-32T-AFO

  • EX4550-32T-DC-AFI

  • EX4550-32T-DC-AFO

Meaning

  • The 32F or 32T in the model number indicates:

    • 32F—The switch has 32 1G/10G SFP+ Ethernet networkports.

    • 32T—The switch has 32 100M/1G/10G BASE-T Ethernetnetwork ports.

  • AFI or AFO in the model number indicates:

    • AFI indicates that the switch is shipped with three fanmodules, each bearing an AFI label.

    • AFO indicates that the switch is shipped with three fanmodules, each bearing an AFO label.

    The labels on the fan modules and power supplies indicate thedirection of airflow in the switch. AIR IN (AFI) labels indicate back-to-front airflow, and AIR OUT (AFO) labels indicatefront-to-back airflow.

  • The DC in the model number indicates that the switch workson DC power supply. Switches that do not have DC in their model numberswork on AC power supply.

EX4550 Switch Hardware and CLI Terminology Mapping

This topic describes the hardware terms used in EX4550 switchdocumentation and the corresponding terms used in the Junos OS CLI.See Table 3.

Table 3: CLI Equivalents of Terms Usedin the Documentation for EX4550 Switches

Hardware Item (CLI)

Description (CLI)

Value (CLI)

Item in Documentation

Additional Information

Chassis

One of the following:

  • EX4550-32F

  • EX4550-32T

Switch chassis

Routing Engine (

  • EX4550-32F

  • EX4550-32T

Routing Engine

FPC (

Abbreviated name of the Flexible PIC Concentrator(FPC)

One of the following:

  • EX4550-32F

  • EX4550-32T

On a standalone switch, the default value is 0.

The switch does not have actual FPCs. In this case, FPCrefers to the switch itself.

On a Virtual Chassis configuration, the values correspondto the assigned member ID of switches in the Virtual Chassis.

In this case, the FPC number refers to the member IDassigned to the switch.

PIC (

Abbreviated name of the Physical Interface Card (PIC)

The switch does not have actual PIC devices; see entriesfor PIC 0 through PIC 2 for the equivalent item on the switch.

  • 32x 1G/10G SFP/SFP+

  • 32x 100M/1G/10G BASE-T

PIC 0

Built-in network ports on the switch.

One of the following:

  • 8x 1G/10G SFP/SFP+

  • 8x 100M/1G/10G BASE-T

  • 2x40GE QSFP+

  • 2x 32GE Virtual Chassis

PIC 1

The expansion module or the Virtual Chassis module installedin the module slot on the front panel of the switch.

One of the following:

  • 8x 1G/10G SFP/SFP+

  • 8x 100M/1G/10G BASE-T

  • 2x40GE QSFP+

  • 2x 32GE Virtual Chassis

PIC 2

The expansion module or the Virtual Chassis module installedin the module slot on the rear panel of the switch.

Xcvr (

Abbreviated name of the transceiver

Optical transceivers

Power supply (

One of the following:

  • JPSU-650W
    -AC-AFO

  • JPSU-650W
    -AC-AFI

  • JPSU-650W
    -DC-AFO

  • JPSU-650W
    -DC-AFI

AFI and

AC power supply or DC power supply.

Fan tray

One of the following:

  • Fan module, Airflow In (AFI)

  • Fan module, Airflow Out (AFO)

Fan module

Note: The EX4550 switch has three fan modules, which are collectivelyreferred to as fan tray in the CLI.